BI-0316 - Mass Storage Module

Appendix D Connector Assignments

VMEbus P1 Assignments
Pin Number(a) Signal Mnemonic(b) Signal Mnemonic(c) Signal Mnemonic
1(D00)(BBSY*)(D08)
2(D01)(BCLR*)(D09)
3(D02)ACFAIL*(D10)
4(D03)BG0IN*(D11)
5(D04)BG0OUT*(D12)
6(D05)BG1IN*(D13)
7(D06)BG1OUT*(D14)
8(D07)BG2IN*(D15)
9GNDBG2OUT*GND
10(SYSCLK)BG3IN*(SYSFAIL*)
11GNDBG3OUT*(BERR*)
12(DS1*)(BR0*)(SYSRESET*)
13(DS0*)(BR1*)(LWORD*)
14(WRITE*)(BR2*)(AM5)
15GND(BR3*)(A23)
16(DTACK*)(AM0)(A22)
17GND(AM1)(A21)
18(AS*)(AM2)(A20)
19GND(AM3)(A19)
20(IACK*)GND(A18)
21IACKIN*(SBUS_DATA)(A17)
22IACKOUT*(SBUS_STRB)(A16)
23(AM4)GND(A15)
24(A07)(IRQ7*)(A14)
25(A06)(IRQ6*)(A13)
26(A05)(IRQ5*)(A12)
27(A04)(IRQ4*)(A11)
28(A03)(IRQ3*)(A10)
29(A02)(IRQ2*)(A09)
30(A01)(IRQ1*)(A08)
31(-12V)(+5V STDBY)+12V
32+5V+5V+5V


Note: Signal mnemonics shown in parenthesis () are not used by the BI0316.

VMEbus P2 Assignments (Single-Ended)
Pin Number(a) Signal Mnemonic(b) Signal Mnemonic(c) Signal Mnemonic
1-DB(12)+5VGND
2-DB(13)GNDGND
3-DB(14)(RETRY)GND
4-DB(15)(A24)GND
5-DB(P1)(A25)GND
6-DB(0)(A26)GND
7-DB(1)(A27)GND
8-DB(2)(A28)GND
9-DB(3)(A29)GND
10-DB(4)(A30)GND
11-DB(5)(A31)GND
12-DB(6)GNDGND
13-DB(7)+5VGND
14-DB(P)(D16)GND
15GND(D17)GND
16GND(D18)GND
17TERMPWR(D19)TERMPWR
18GND(D20)GND
19-ATN(D21)GND
20GND(D22)GND
21-BSY(D23)GND
22-ACKGNDGND
23-RST(D24)GND
24-MSG(D25)GND
25-SEL(D26)GND
26-C/D(D27)GND
27-REQ(D28)GND
28-I/O(D29)12V
29-DB(8)(D30)GND
30-DB(9)(D31)GND
31-DB(10)GNDGND
32-DB(11)+5VGND

Note: Signal mnemonics shown in parenthesis () are not used by the BI0316.

VMEbus P2 Assignments (Differential)
Pin Number(a) Signal Mnemonic(b) Signal Mnemonic(c) Signal Mnemonic
1-DB(12)+5V+DB(12)
2-DB(13)GND+DB(13)
3-DB(14)(RETRY)+DB(14)
4-DB(15)(A24)+DB(15)
5-DB(P1)(A25)+DB(P1)
6GND(A26)GND
7-DB(0)(A27)+DB(0)
8-DB(1)(A28)+DB(1)
9-DB(2)(A29)+DB(2)
10-DB(3)(A30)+DB(3)
11-DB(4)(A31)+DB(4)
12-DB(5)GND+DB(5)
13-DB(6)+5V+DB(6)
14-DB(7)(D16)+DB(7)
15-DB(P)(D17)+DB(P)
16GND(D18)DIFFSENS
17TERMPWR(D19)TERMPWR
18-ATN(D20)+ATN
19GND(D21)GND
20-BSY(D22)+BSY
21-ACK(D23)+ACK
22-RSTGND+RST
23-MSG(D24)+MSG
24-SEL(D25)+SEL
25-C/D(D26)+C/D
26-REQ(D27)+REQ
27-I/O(D28)+I/O
28GND(D29)12V
29-DB(8)(D30)+DB(8)
30-DB(9)(D31)+DB(9)
31-DB(10)GND+DB(10)
32-DB(11)+5V+DB(11)

Note: Signal mnemonics shown in parenthesis () are not used by the BI0316.

P3, P5-P6 SCSI-3 Connectors (Single-Ended)
Signal MnemonicPin NumberPin NumberSignal Mnemonic
GND135-DB(12)
GND236-DB(13)
GND337-DB(14)
GND438-DB(15)
GND539-DB(P1)
GND640-DB(0)
GND741-DB(1)
GND842-DB(2)
GND943-DB(3)
GND1044-DB(4)
GND1145-DB(5)
GND1246-DB(6)
GND1347-DB(7)
GND1448-DB(P)
GND1549GND
GND1650GND
TERMPWR1751TERMPWR
TERMPWR1852TERMPWR
RESERVED1953RESERVED
GND2054GND
GND2155-ATN
GND2256GND
GND2357-BSY
GND2458-ACK
GND2559-RST
GND2660-MSG
GND2761-SEL
GND2862-C/D
GND2963-REQ
GND3064-I/O
GND3165-DB(8)
GND3266-DB(9)
GND3367-DB(10)
GND3468-DB(11)

P3, P5-P6 SCSI-3 Connectors (Differential)
Signal MnemonicPin NumberPin NumberSignal Mnemonic
+DB(12)135-DB(12)
+DB(13)236-DB(13)
+DB(14)337-DB(14)
+DB(15)438-DB(15)
+DB(P1)539-DB(P1)
GND640GND
+DB(0)741-DB(0)
+DB(1)842-DB(1)
+DB(2)943-DB(2)
+DB(3)1044-DB(3)
+DB(4)1145-DB(4)
+DB(5)1246-DB(5)
+DB(6)1347-DB(6)
+DB(7)1448-DB(7)
+DB(P)1549-DB(P)
DIFFSENS1650GND
TERMPWR1751TERMPWR
TERMPWR1852TERMPWR
RESERVED1953RESERVED
+ATN2054-ATN
GND2155GND
+BSY2256-BSY
+ACK2357-ACK
+RST2458-RST
+MSG2559-MSG
+SEL2660-SEL
+C/D2761-C/D
+REQ2862-REQ
+I/O2963-I/O
GND3064GND
+DB(8)3165-DB(8)
+DB(9)3266-DB(9)
+DB(10)3367-DB(10)
+DB(11)3468-DB(11)

P7-P10 SCSI-2 Connectors (Single-Ended)
Signal MnemonicPin NumberPin NumberSignal Mnemonic
GND12-DB(0)
GND34-DB(1)
GND56-DB(2)
GND78-DB(3)
GND910-DB(4)
GND1112-DB(5)
GND1314-DB(6)
GND1516-DB(7)
GND1718-DB(P)
GND1920GND
GND2122GND
RESERVED2324RESERVED
OPEN2526TERMPWR
RESERVED2728RESERVED
GND2930GND
GND3132-ATN
GND3334GND
GND3536-BSY
GND3738-ACK
GND3940-RST
GND4142-MSG
GND4344-SEL
GND4546-C/D
GND4748-REQ
GND4950-I/O

P7-P10 SCSI-2 Connectors (Differential)
Signal MnemonicPin NumberPin NumberSignal Mnemonic
GND12GND
+DB(0)34-DB(0)
+DB(1)56-DB(1)
+DB(2)78-DB(2)
+DB(3)910-DB(3)
+DB(4)1112-DB(4)
+DB(5)1314-DB(5)
+DB(6)1516-DB(6)
+DB(7)1718-DB(7)
+DB(P)1920-DB(P)
DIFFSENS2122GND
RESERVED2324RESERVED
TERMPWR2526TERMPWR
RESERVED2728RESERVED
+ATN2930-ATN
GND3132GND
+BSY3334-BSY
+ACK3536-ACK
+RST3738-RST
+MSG3940-MSG
+SEL4142-SEL
+C/D4344-C/D
+REQ4546-REQ
+I/O4748-I/O
GND4950GND

P11-P12 Power Connectors
Signal MnemonicPin Number
+5V1
GND2
GND3
+12V4

P14 Drive Options Jumper Block
Signal MnemonicPin NumberPin NumberSignal Mnemonic
D1TERM12GND
GND34GND
D1SYNC56D2SYNC
D1SYNC78D2SYNC
D2TERM910GND

P15-P16 Drive Options Connector
Signal MnemonicPin NumberPin NumberSignal Mnemonic
SEL0-12XTFALT-
SEL1-34VUNIQ-
SEL2-56SPSYNC-
SEL3-78XTACTV-
ENTERM-910GROUND
+5V1112FAULT-


BI-0316 - Mass Storage Module - 6 DEC 1996 Copyright © 1996 Brand Innovators B.V. [Next] [Previous] [Top] [Contents] [Back]