|
[Next] [Previous] [Up] [Top] [Contents] [Back] 4.4 Jumper Settings 4.4.1 Jumper JB1 - Access ModeWhen the connection is made between pins 1 and 2 of JB1, the module will respond to both Supervisory AM code $2D and non privileged AM code $29. When pins 2 and 3 are connected, the module will respond only to the Supervisory AM code $2D.
Figure 4-1 Jumper JB1 - Access Mode
BI-0433 - 12 Channel Incremental Encoder Interface with Isolated Inputs and Cable Fault Detection - 23 MAY 1997 Copyright © 1997 Brand Innovators B.V. [Next] [Previous] [Up] [Top] [Contents] [Back]
|