[Next] [Previous] [Up] [Top] [Contents]  [Back]   
Chapter 2  Specifications 
 2.4  Input Specifications
- Input Signals
- Differential Mode Receivers conform to RS-422-A
 
 - Maximum Differential Voltage: 5 V
 
 - Single ended input signals are possible
 
 - Detection of non-differential signal on all inputs
 
  
  
- Input Frequency
- Maximum Frequency on all inputs: 1 Mhz
 
  
  
- Insulation
- Input Signal to System:
 Optocoupler HCPL-2631 Recognized under the Component Program of U.L.(File No. E55361) for Dielectric Withstand Proof Test Voltages of 2500 VAC, 1 Minute, RH  50%, TA = 25 °
 
  
  
 
  
BI-0433 - 12 Channel Incremental Encoder Interface with Isolated Inputs and Cable Fault Detection - 23 MAY 1997
Copyright © 1997 Brand Innovators B.V.
[Next] [Previous] [Up] [Top] [Contents]  [Back]  
  
 |